![dexis platinum sensor calibration files download dexis platinum sensor calibration files download](https://m.media-amazon.com/images/I/81UqR9I6AtL.jpg)
- Dexis platinum sensor calibration files download install#
- Dexis platinum sensor calibration files download driver#
- Dexis platinum sensor calibration files download manual#
- Dexis platinum sensor calibration files download software#
- Dexis platinum sensor calibration files download professional#
Dexis platinum sensor calibration files download driver#
NOTE: DTX Studio does not require the KaVo IO sensor driver to complete installation. Call if you have any questions on the installation process.
Dexis platinum sensor calibration files download install#
INSTALLATION STEPS for DTX Users Visit go. and login in to your DTX Studio Go account in order to install your KaVo IXS sensor.
Dexis platinum sensor calibration files download software#
Reboot your computer to complete the software installation for your new KaVo IXS sensor. STEP 6 STEP 7 Right click on the KaVo IO sensor driver and select Run as Administrator. NOTE: You will NOT need to uninstall your previous version of your Imaging acquisition software in advance. STEP 5 Open your Imaging acquisition software to install your update. The filename for the driver is KaVO_IO-Sensor.exe. STEP 4 Download the latest version of the KaVo IO Sensor Driver by searching for KaVo IXS. DEXIS 9 and DEXIS Imaging Suite DEXIS 10 ). NOTE: DO NOT attempt to switch between Imaging Software Platforms (i.e. STEP 3 Navigate to and download the latest version of your Imaging acquisition software, according to the version that you are currently using. Open your supported Imaging Software and verify that you have the minimum version installed. 3Ĥ INSTALLATION STEPS for CLINIVIEW Users and Users without USB Software Kit Access STEP 1 STEP 2 Log into your computer with an Administrator account. STEP 7 Reboot your computer to complete the software installation for your new KaVo IXS sensor. Note: If your Imaging Software s status is listed as Modified, the software was successfully installed but you can still install additional purchased software add-ons. STEP 6 Verify that your Imaging Software and KaVo IO Sensor Driver were successfully installed by viewing the KaVo Software Manager. Be sure to follow all prompts during the installation process. STEP 5 KaVo Software Manager will begin installing the latest version of both your Imaging Software and KaVo IO Sensor Driver. STEP 4 From the thumb drive, right click the KaVo Software Manager shortcut and select Run As Administrator. If you no longer have access to your USB Software Kit, you will need to follow the steps in the section on the following page, to download the software and copy a version to your workstation. If your workstation is not connected to the Internet, you will need to contact KaVo Technical Support. CAUTION: You will need a valid Internet connection to perform the installation. Simply insert this thumb drive into your computer to begin installation. Your KaVo IXS sensor comes with KaVo Software Manager on the USB Software Kit. If you are installing a new Imaging Software for the 1st time, it is recommended to complete the installation prior to installing your KaVo Software IO sensor drivers. 2ģ INSTALLATION STEPS - DEXIS and VixWin Users STEP 1 STEP 2 STEP 3 Log into your computer with an Administrator account. Contact your software manufacturer or KaVo Technical Support for software and installation instructions. CAUTION Some dental imaging software use a 3rd party SDK to integrate with KaVo IXS. If you need additional USB extension cables, call KaVo Technical Support and order part number IMAGING SOFTWARE To install the KaVo IXS sensor, you will need either: 4VixWin or higher 4DEXIS or higher 4DEXIS or higher 4DTX 1.6 or higher 4CLINIVIEW and KaVo Driver 20.1 or higher NOTE: DEXIS 11, VixWin 4 and CLINIVIEW 10 does not support KaVo IXS All of the above software, as well as the Quick Start Guide and User Manual, are on the KaVo Download Center: NOTE: There should not be a need to uninstall previously loaded software. We recommend using the USB extension cable that came with your KaVo IXS Kit. A USB extension cable may be required for data/power continuity. CAUTION Some USB 2.0 ports may not deliver consistent power or data continuity. USB USB 2.0/3.0 Ports NOTE: USB 1.0 ports are not supported for KaVo IXS sensors. Operating systems should be current with the latest Windows updates.
Dexis platinum sensor calibration files download professional#
COMPUTER ENVIRONMENT The following operating systems are supported: 4Windows 7 Professional (32/64-bit) 4Windows 8.1 Professional (32/64-bit) 4Windows 10 Professional (32/64-bit) NOTE: Operating systems should be Professional series and not a Home edition.
Dexis platinum sensor calibration files download manual#
Reference your KaVo IXS User Manual (included in the box) for additional information on sensor use. Please review the system requirements prior to proceeding with this installation. 2 SYSTEM REQUIREMENTS To ensure your new KaVo IXS sensor is installed properly, please follow the steps below.